VIBE VB-B8283JDGG 8-BAY SATA HDD RAID ENCLOSURE
- FOR 2.5"/3.5" SATA HDD TO USB 3.0 + eSATA
Model: VB-B8283JDGG
( RAID LEVEL: RAID 00, 30, 50, Clean, Large) Up to 8x3TB
FREE - HORNETTEK HT-PCIU3N 2-Ports USB 3.0 PCIE CARD
DESIGNED AND MADE IN TAIWAN
Features:
● Universal fitting for Five 2.5"/3.5" SATAI/II HDD (3TB x8)
● Hardware Raid, supporting RAID 00, 30, 50, Clean, JBOD(Large)
● New USB 3.0 and eSATA combo interface
● Over 200MB/s read and 170MB/s write performance.
● Backwards compatible with USB 2.0.
● Mobile HDD tray Design
● 8 x Hot Swappable Hard Drive Trays
● Supports Port Multiplier function
● Back Panel DIP Switch RAID setting
● Over 2TB per volume via eSATA and USB on OS that support 2TB and above.
● Automatic insertion / removal detection and rebuild.
● Hardware RAID with standard Interface. No extra drivers required.
● Compact, stylish 8 bay tower design with protective ventitating cover
● Built-in 12cm Cooling Fan
● Material: Full SECC casing, metal shielding and ABS front Panel
● OS Supports : XP/Vista/7, MAC OS 10.X or above
● Internal Power Supply:115~230V, 300W
● Safety Approvals: CE,FCC, UL, CB, RoHS
Specification:
Package Contents:
1. VB-B8283JDGG RAID BOX
2. UK Power Cord
4. eSATA Cable
5. USB 3.0 Cable
6. eSATA Bracket
7. User's Manual & Utility CD
8. Some Screwss for HDD installation
User's Manual (PDF File) : Download
Storage Policies:
You can configure the VB-B8283JDGG storage appliance to use any of the following storage policies to map the appliance’s physical hard drives to virtual drives that are visible to the host computer. The virtual drives are called volumes. The host operating system treats each volume as if it were a single physical drive. This virtualization allows you to overcome restrictions that are imposed by physical hard drives, such as speed, storage capacity or data storage reliability.
CLEAN MODE
The CLEAN MODE storage policy enables each hard drive to be seen separately as one drive. When using a SATA host controller, CLEAN MODE should only be used if the SATA host controller provides Port Multiplier (PM) support. If a host is not PM-aware, only a single drive is presented (drive 1). No such limitation if using a USB host connection.
The CLEAN MODE storage policy is available for a standalone (non-cascaded) storage or the top-level node of a cascaded configuration, but not for subordinate nodes. Even though you can use the MODE SWITCH to select CLEAN MODE for any node in a cascaded configuration, only the first CLEAN MODE volume of any subordinate node is detected by your host. Therefore, selecting CLEAN MODE for any subordinate node is not recommended.
In a CLEAN MODE configuration, the VB-B8283JDGG storage appliance directly exposes each physical drive.
The CLEAN MODE will not clean up the drives partition if the drives were use as single drive before.
LARGE MODE
The LARGE MODE storage policy concatenates a series of physical hard drives as a single large volume; resulting in a seamless expansion of virtual volumes beyond the physical limitations of singularly connected hard drives. VB-B8283JDGG storage policy delivers maximum storage space without a single large capacity and costly hard drive.
Any node within a cascaded configuration can be set to LARGE MODE.
Hard drives 1 to 8 are concatenated into a single virtual volume in the Figure below with a storage capacity that is equal to the sum of each of the physical hard drives 1 to 8.
It is also possible to create a LARGE volume using only a single hard disk drive connected to Port 1. However, it is not possible to expand an existing LARGE volume by adding another hard disk drive and still preserve any existing data on that volume.
R00 MODE
The R00 MODE storage policy distributes access across all hard disks by three RAID systems. R00 MODE presents the best data speed but no data redundancy. R00 MODE storage policy accelerates hard disk drive operating speed by using many disks in parallel. Hard disk drive data segments are written to different disks simultaneously which increases performance while sacrificing data redundancy.
To implement the R00 MODE storage policy, the VB-B8283JDGG Storage first creates 2 single virtual volumes that are striped across hard drive(s) on SYS1 and SYS2 individually, and then striped across both virtual volumes again.
It is also possible to create a R00 volume using only a single hard disk drive connected to Port 1. However, the VB-B8283JDGG storage appliance directly exposes 1 physical drive, and it will clean up the drives partition even if the drives were use as single drive before.
R30 MODE
The R30 MODE adds fault tolerance to drive striping by including parity information with the data. R30 MODE dedicates the equivalent of two drives for storing parity stripes on both systems (SYS1 and SYS2), and then stripe the systems together. The data and parity information are arranged on the drive arrays so that paritys are written to two drives on both systems (SYS1 and SYS2). The following example illustrates how the parity is rotated from drive to drive.
The R30 MODE uses less capacity for protection and is the preferred method to reduce the cost per megabyte for larger installations.
In exchange for low overhead necessary to implement protection, the R30 MODE degrades performance for all write operations. The parity calculations for R30 MODE may result in read performance that is somewhat slower than the write performance.
The resulting storage capacity of the virtual R30 volume will be N-2 times (“N” is the number of drive) of the smallest drive.
If one drive fails, the virtual R30 volume is still usable, but it is in a vulnerable state because its mirrored hard drive is inaccessible. When the offline drive comes back online, the appliance begins a rebuild process immediately to restore data redundancy. A message appears in the LED indicator to notify you that a rebuild is in progress.
Although the volume remains available during the rebuild process, the volume is susceptible to data loss through damage to the remaining drive until redundancy is restored at the end of the rebuild and verification process. Host access takes precedence over the rebuild process. If you continue to use the virtual R30 volume during the rebuild, the rebuild process will take a longer time to complete, and the host data transfer performance will also be affected.
It is also possible to create a R30 volume using only a single hard disk drive connected to Port 1. However, the VB-B8283JDGG storage appliance directly exposes 1 physical drive, and it will clean up the drives partition even if the drives were use as single drive before.
R50 MODE
The R50 MODE adds fault tolerance to drive striping by including parity information with the data. R50 MODE dedicates the equivalent of one drive for storing parity stripes on both systems (SYS1 and SYS2), and then stripe the systems together. The data and parity information is arranged on the drive array so that parity is written to all drives on both systems (SYS1 and SYS2). The following example illustrates how the parity is rotated from drive to drive.
The R50 MODE uses less capacity for protection and is the preferred method to reduce the cost per megabyte for larger installations.
In exchange for low overhead necessary to implement protection, the R50 MODE degrades performance for all write operations. The parity calculations for R50 MODE may result in read performance that is somewhat slower than the write performance.
The resulting storage capacity of the virtual R50 volume will be N-2 times (“N” is the number of drive) of the smallest drive.
If one drive fails, the virtual R50 volume is still usable, but it is in a vulnerable state because its mirrored hard drive is inaccessible. When the offline drive comes back online, the appliance begins a rebuild process immediately to restore data redundancy. A message appears in the LED indicator to notify you that a rebuild is in progress.
Although the volume remains available during the rebuild process, the volume is susceptible to data loss through damage to the remaining drive until redundancy is restored at the end of the rebuild and verification process. Host access takes precedence over the rebuild process. If you continue to use the virtual R50 volume during the rebuild, the rebuild process will take a longer time to complete, and the host data transfer performance will also be affected.
It is also possible to create a R50 volume using only a single hard disk drive connected to Port 1. However, the VB-B8283JDGG storage appliance directly exposes 1 physical drive, and it will clean up the drives partition if the drives were use as single drive before.
Remark:If you want to change Raid mode setting (data stored will be totally lost due to re-building of the RAID), please DO back up all data before changing Raid mode.
註: 超過2TB容量,請選用64bit OS, 如Windows Vista / 7 (64 bit)
Specifications subject to change without notice. For reference only